Cylinder I.D. A A1 A2 B C D D1 E F G H I J K
(mm)
20 131 122 110 40 70 21 12 28 12 16 20 12 6 M 8×1.25
25 135 128 114 44 70 21 14 30 14 16 22 17 6 M10×1.25
14 32 141 128 114 44 70 27 14 30 14 16 22 17 6 7 M10×1.25 14
40
22
46
24
138
165
32
152
14
17
M12×1.25
14
27
92
Air Cylinders / Valves / Regulators / Shock Absorbers / O-Rings Cylinder I.D. M22×1.25 M 10 8 8 16 19 R1 12 29 U 10 8 10 6 8 G1/8 AR AX AY Shock Absorbers / O-Rings Air Cylinders / Valves / Regulators /
V
R
L
S
Q
P
X
W
(mm)
20
10
29
10
33
7
25
19
12
12
12
34
16
M22×1.5
29
G1/8
33
7
32
M24×2.0
15
16
8
37
12
25
G1/8
39.5
12
12
32
40
12
M30×2.0
12
12
25
Cylinders and Accessories QCylinder Theoretical Output Force Table 20 0.3 Air pressure MPa 15 0.5 49.5 0.6 16 0.7 14 G1/4 8 47 41 Accessories Cylinders and
Cylinder I.D. Operating Compression area
(mm 2 )
Type
(mm)
0.2
0.1
0.4
94.2
P.951 20 Push 314.0 31.4 62.8 147.2 125.6 157.0 188.4 219.8 P.951
52.8
158.3
Pull
79.1
131.9
184.6
26.4
105.5
263.8
Push
343.4
196.3
294.4
490.6
49.1
98.1
245.3
25
Pull
82.4
Shock Absorber 32 Push 412.1 41.2 160.8 123.6 164.9 206.1 247.3 288.5 Absorber Shock
321.5
562.7
803.8
482.3
401.9
241.2
80.4
414.5
483.6
276.3
345.4
138.2
207.2
69.1
Pull
690.8
40 Push 1256.0 125.6 251.2 376.8 502.4 628.0 753.6 879.2
Pull
1055.0
P.991 QCylinder Specifications 105.5 211.0 316.5 422.0 527.5 633.0 738.5 P.991
Rod End Bearings Operating Type Double Acting Bearings Rod End
20~40
Cylinder I.D. (mm)
Fluid Used
Operating Pressure Range Mpa(psi) Air (filtered through the filter screen of 40 μm)
0.15~1 (14~145)
P.999 Guaranteed Pressure Resistance Mpa(psi) 1.5(215) P.999
Operating Temperature °C
-20~70
Floating Joint Operating Speed Range mm/s 0~150 0 >0~150 0 Floating Joint
30~800
+1.0
+1.5
Stroke Tolerance Range
Cushion Mechanism
Anti-collision pad
P.1004 QMagnetic Switch Specification P.1004
Item Electronic Sensor Reed Sensor
Type 2-Wire Type NPN 3-Wire Type PNP 3-Wire Type 2-Wire Type
Silencer Voltage 2.5mA~100mA 30/200mA Max. 5V~240V AC/DC Silencer
5V~30V DC
10V~28V DC
Max. Switching Current
100mA
Max. Contact Capacity
6W Max.
-
3mA Max.
Internal Consumption Current 2.8W Max. 5mA Max. 10W Max.
P.1006 Leakage Current 0.05mA Max. 0.01mA Max. - P.1006
Power polarity reverse protection, surge absorption protection
Protection Circuit
Control Valves and Accessories Operating Temperature General IP64 and Accessories Control Valves
-10°C~70°C
Protection Rating
P.1007 P.1007
Air Source Handling Handling Air Source
P.1015 P.1015
O-Rings O-Rings
P.1027 P.1027
Register an Account Technical Support Sales Inquiry Contact Us:
Tel: (65) 6733 7211
Website: sg.misumi-ec.com
Hours: 9am - 6pm (Mon - Fri) 972
bit.ly/RegisterMISUMIaccount techsupport@misumi.com.sg cs@misumi.com.sg 9am - 3pm (Sat)