           Step 3. Calculate free span length            <Selection Examples>
          Calculate the length of free span by required moving stroke and      2000mm is required for strokes. Free span length requires
                                                          2000/2=1000mm
          the position of fixed end.                      as the fixed end can be set at a stroke intermediate point.
                           S (Travel Stroke)       <Free Span Length>
                        S/2          S/2            Distance between the cable carrier moving end (A) and bending
                                Free Span Length    radius arc origin point (B).
                             (B)            (A)
                                                    When positioning the fixed end in the center of the moving stroke,
                R                                     Free Span Length = Travel Stroke/2

                   Moving End
                                Fixed End  Moving End  * Possible to minimize the quantity of cable carrier links by setting
                                                     the fixed end at the intermediate point of travel stroke.
    3      Step 4. Calculate the required number of links                                                                                                                                                  3
    Cable Carriers / Cables / Heat Shrink Tubes   Fans / Network USB Adapter / Switching Hubs  Calculate the required number of links by the following formula.  S (Travel Stroke) Expansion  Moving End  H(*)  HF(*)  Fans / Network USB Adapter / Switching Hubs  Cable Carriers / Cables / Heat Shrink Tubes
                 S
                  +K+A
                                                                          Free Span
                 2
               n=
                   P
                                                                      R
           n: Number of Links (Round up the number after the decimal point.)
                                                                         Fixed End
           S: Travel Stroke
           K: Arc Length + Margin (*)
           A:  Distance from an intermediate point (mm) when              A  S/2
             fixed end is not set at a travel stroke intermediate point
    Cable   Carriers  P: Link Pitch(*)                 E  Symbols in the diagram: HF indicates the passable height that                                                                                   Carriers  Cable
             (0 when at an intermediate point).
          *1 About the number of backup links            takes into account the expansion height generated with cables /
          ·  In the case of new designs, there may be a possibility that carrier   hoses, etc. not inserted, when using the cable carrier at a free
   P.445  links run short.                               span length.                                                                                                                                     P.445
          ·  It is recommended that links are selected longer by one or two   *  Please refer to the product pages for the symbols K
    Machinery   Cables  · For installation, see product pages.  (arc length + margin), P (link pitch) and H-HF (space height).                                                                            Cables  Machinery
          links, and are adjusted (removed) at the time of installing device.
            Precautions for installing and fixing cables
   P.455  ·  Tie a cable at both ends of the cable carrier.                                                                                                                                               P.455
    Cables for   Signals  Fix                                                                                                                                                                             Signals  Cables for


   P.461          Fix                                                                                                                                                                                     P.461
    Heat Shrink   Tubes  ·  Allow the cable to move freely.                                                                                                                                               Tubes  Heat Shrink




          the cable carrier.
   P.468  ·  For the full stroke range, make sure that any portion of a cable is not put in excessive contact with the internal/external circumference of                                                 P.468
             Cable       ·  No excessive      ·  Excessive contact with the   ·  Excessive contact with the
             Carriers
     Fans    Cable        contact             internal circumference        external circumference                                                                                                         Fans
                                                    ×
                                                                                 ×
   P.480                             ·  Fix both ends of the cable with no tension force applied.                                                                                                         P.480
    Network   Communication                                                                                                                                                                               Communication  Network



   P.484                                                                                                                                                                                                  P.484
    Switching   Hubs                                                                                                                                                                                      Hubs  Switching



   P.489                                                                                                                                                                                                  P.489




    447
   447   448   449   450   451   452   453   454   455   456   457