Page 451 - MISUMI SINGAPORE Economy Series
P. 451

Economy series   Product Overview  Technical Calculation                      Economy series
 Cable Carriers                                                                  Cable Carriers



         QWhat is the Cable Carrier?
 Economy series   Saving  ·  It can prevent the cable and wire tubes connected to the moving parts of the equipment from twisting, stretching and entanglement due
 vs Standard Type
           to movement.
          ·  I t is suitable for supporting and guiding multiple cables connected to the linear motion part.
 up to
          ·  MISUMI Cable Carrier can be ordered simply by specifying the applicable single type and no need to select the part numbers for the
 Cable Carriers  75 %  QCable Carrier Selection
           link and mounting bracket, respectively.
 Shipment after assembly  Step 1. Tentatively select cable carrier type.

 Assembled products shipped   Step 2. Select cable carrier size.
 in a short delivery time,                                   If required sizes are not available, select a different
                                                             type of cable carrier.
 eliminating troublesome link   Step 3. Calculate free span length
 3  · C- : Light & Low load Series  MISUMI logo model engraved  Step 4. Calculate the required number of links  3
 connections.
 Cable Carriers / Cables / Heat Shrink Tubes   Fans / Network USB Adapter / Switching Hubs  · E- : Medium Load Series  Selection completed  Fans / Network USB Adapter / Switching Hubs  Cable Carriers / Cables / Heat Shrink Tubes

 · Low dust & Low Noise Series

          Step 1. Tentatively select cable carrier type.
          Please tentatively select types referring to the following features, open-close methods and sizes.
               Type                        Features                      Flap Open-Close System
 Cable   Carriers  Slit Type  Cables/hoses can be easily inserted in from both external and   Insert the cable into the opening.  Carriers  Cable
         C-MSU
                         Low noise featuring internal noise reduction structure
         C-MSD           internal circumference sides.
 P.445                                                                                             P.445
 Machinery   Cables  Flap Closed Type  Space-saving design enables protection and guide even for only   Flaps do not open.  Cables  Machinery
                         one cable/hose.
         C-MHF
                         Closed type, stronger resistance to twisting
 P.455                                                             Flaps open from either right or left.  P.455
 Cables for   Signals                                                                              Signals  Cables for


                         Open along the inner or outer side of the bending radius
         C-MPU
 P.461   Flap Open-Close Type  The cover can be opened and closed on the left and right.           P.461
         C-MPD
                         Low noise featuring internal noise reduction structure
 Heat Shrink   Tubes                                                                               Tubes  Heat Shrink

 P.468                                                                                             P.468
          Step 2. Select cable carrier size.                     <Selection Examples>
 Fans     Select suitable Cable Carrier size for housing cables/hoses.    One φ20mm cable needs to be stored.  Fans
                                                                     20/0.8=25 or more interior height is required
                                                                   for the condition
                                                                   that the cable O.D. must be within 80% of
 P.480                                 <Size Selection Tips>       interior height.                P.480
 Network   Communication  100%  80%  d  1Height                                                    Communication  Network
                                         O.D. of the cable / hose must be 80% or less than the interior height of the cable carrier.
                                       2Occupied Space
                                          Cable / hose must be within 60% of Cable Carrier Interior Content = Interior Height × Interior Width. (In addition,
                                        for MPSPS, up to 70% of the cable carrier interior can be taken up.)
 P.484   Above 10% of d   Above 10% of d  3Bending Radius                                          P.484
                                          When housing different types of cables/hoses together, please select the cable carrier bending radius to meet
                                        the maximum bending radius.
 Switching   Hubs  *  For sectional dimensions and bending   4Distance Between the Running Cable/Hose and Interior Wall  Hubs  Switching
                                          The distance between the running cable/hose and Cable Carrier interior wall must be at least 10% of the
          radius by type and size, please refer to
                                        running cable / hose O.D.
          product pages.
                                       5 Cable / Hose Mutual Distances
                                         The distance between adjacent cables/hoses must be at least 10% of the biggest cable O.D..
 P.489                                                                                             P.489