Page 1551 - MISUMI SINGAPORE Economy Series
P. 1551
Temperature Sensors Standard Screw Mount PT100 Type
Representative model: C-MSNDPML6-2
Shipping
17.66 SGD 1 day
from
Volume Discount
Quantity 1~9 10~
Discount Unit Price 30%
E Shipping days may differ by Quantity.
E Quantity of volume discount above is for representative Part No. It may differ by the Part.
F
Stainless steel nickel
Armored Tube plated spring 60
L 10 48 Red (-)
3 Red (-)
Lead Wire
Screw M6 Blue (+)
Heat Shrink Tube M4 Y-Shaped Crimp Terminal 22
Part Number Wire Length Temperature
Type F(m) Screw Size L(mm) Sensor Type Range Heat Insulating Plates Heaters / Temperature Sensors /
1
C-MSNDPML6 2 M6×1.0 65 PT100 0~200°C Heaters Cartridge
P.1529
5 Sensors Temperature
Ordering
Example Part Number (Type) - Wire Length F(m) P.1537
C-MSNDPML6 - 2
QPrecautions Controllers Temperature
E Please keep the upper limit of the temperature below the temperature measurement range of the product. If the casing temperature
exceeds the heat-resistant temperature, there is high possibility to cause wire breakage problem.
E If the temperature of heat generating parts exceeds 100°C, please choose the specification with a front end as long as possible. P.1551
QUsage Method
Thermocouples should not be installed too close to the heater, the installation depth should be at least 8 to 10 times the diameter of
the armored tube. The gap between the armored tube and the thermocouple wall if not filled with insulation may cause overheating or Plates Heat Insulation
cold air to enter the heating chamber. Therefore, this gap must be filled with insulating material such as insulating earth or asbestos
to stabilize the heat in the chamber. Air convection affects the accuracy of the heating process. The sleeve should not be installed too
close to the heating chamber to avoid exceeding 100°C. The installation of the thermocouple should be avoided as much as possible
from strong magnetic and electric fields. Therefore, the thermocouple and power cable should not be installed close to each other P.1555
to avoid errors caused by signal interference. Do not install the thermocouple with the media. When measuring the gas temperature
inside the tube, the thermocouple needs to be installed in the opposite direction of circulation and in full contact with the gas.
How to search Search on MISUMI official website Step 1 Input Search Keyword Step 2 Select Brand Brand
on website By By MISUMI
Type C-MSNDPML6 Keyword temp sensor Economy series
Register an Account Technical Support Sales Inquiry Contact Us:
Tel: (65) 6733 7211
Website: sg.misumi-ec.com
Hours: 9am - 6pm (Mon - Fri) 1546