Temperature Sensors Round Terminal Bendable K-Thermocouple
Representative model: C-MFMT4
Save Up to
vs Standard Type 74% Shipping
7.98 SGD 1 day
from
Volume Discount
Quantity 1~29 30~
Discount Unit Price 30%
E Shipping days may differ by Quantity.
E Quantity of volume discount above is for representative Part No. It may differ by the Part.
F
60
Terminal Heat Shrink Tube
Screw 48 Lead Wire Red (+)
Silicon Rubber Sheath (Green)
Stainless steel nickel plated spring Blue (-)
M4 Y-Shaped Crimp Terminal
Round Type Crimp Terminal 22
Part Number Terminal Wire Length F(m) Sensor Type Temperature Range
Type No. Screw Size
4 M4 1 Heat Insulating Plates Heaters / Temperature Sensors /
C-MFMT K-Thermocouple 0~150°C
4-5 M5 5 Heaters Cartridge
Ordering P.1529
Example Part Number (Type · No.)
C-MFMT4
QPrecautions Sensors Temperature
E To connect long thermocouple wires, be sure to use the compensating wire.
E Please strictly observe the heat resistant temperature of each part in product page. Please note that even the upper limit of the
temperature measurement is very high, if the heat-resistant temperature is exceeded, it may occur wire breakage or disconnection P.1537
problems.
E Do not apply large external force or vibration.
E Please pay attention to the heat resistance temperature of the sleeve part.
E Please keep the upper limit of the temperature below the temperature measurement range of the product. If the casing temperature Controllers Temperature
exceeds the heat-resistant temperature, there is high possibility to cause wire breakage problem.
E If the temperature of heat generating parts exceeds 100°C, please choose the specification with a front end as long as possible.
QUsage Method P.1551
Thermocouples should not be installed too close to the heater, the installation depth should be at least 8 to 10 times the diameter of
the armored tube. The gap between the armored tube and the thermocouple wall if not filled with insulation may cause overheating or
cold air to enter the heating chamber. Therefore, this gap must be filled with insulating material such as insulating earth or asbestos
to stabilize the heat in the chamber. Air convection affects the accuracy of the heating process. The sleeve should not be installed too Plates Heat Insulation
close to the heating chamber to avoid exceeding 100°C. The installation of the thermocouple should be avoided as much as possible
from strong magnetic and electric fields. Therefore, the thermocouple and power cable should not be installed close to each other
to avoid errors caused by signal interference. Do not install the thermocouple with the media. When measuring the gas temperature P.1555
inside the tube, the thermocouple needs to be installed in the opposite direction of circulation and in full contact with the gas.
How to search Search on MISUMI official website Step 1 Input Search Keyword Step 2 Select Brand Brand
on website By By
Type C-MFMT Keyword temp sensor MISUMI
Economy series
Register an Account Technical Support Sales Inquiry Contact Us:
Tel: (65) 6733 7211
Website: sg.misumi-ec.com
Hours: 9am - 6pm (Mon - Fri) 1542
bit.ly/RegisterMISUMIaccount techsupport@misumi.com.sg cs@misumi.com.sg 9am - 3pm (Sat)